Which KNX devices can Baccata program?

2004 product databases from 48 manufacturers, 5330 products, 4576 application programs, checked offline against the current code. Baccata refuses any device it cannot fully program and read back, so "supported" here is the test the app itself applies.

8bus-tested (0%)
3831supported (84%)
370not yet (8%)
367needs ETS plugin (8%)
bus-tested
programmed with Baccata and read back byte-for-byte on a real bus.
supported
programming model and every load step implemented. Should work; nobody has tried it on hardware yet.
not yet
a programming model (BCU2, System 300, couplers) or a load step I have not implemented. Fixable; a packet capture helps most.
needs ETS plugin
the product is configured by a manufacturer ETS plugin, a DLL inside the product database. Its logic is not in the XML, so there is nothing to reproduce. Blocked for good.
parser fails
my parser raises on the product database. A bug on my side.
unswept
not swept yet.

By manufacturer

Only manufacturers whose product databases I have. Click a name for its products, or use the product search.

manufacturerproductsprogramsbus-testedsupportednot yetpluginfailswhy not
Zennio89189187417MV-0912 (Bcu1) (12), MV-091A (Bcu1) (5)
Hager Electro68458436212210ETS plugin (210), MV-0025 (Bcu2) (4), MV-091A (Bcu1) (4), MV-0912 (Bcu1) (4)
Berker6304953821796ETS plugin (96), MV-0021 (Bcu2) (7), MV-0001 (None) (6), MV-0912 (Bcu1) (2), MV-091A (Bcu1) (2)
ABB434407392411ETS plugin (11), MV-091A (Bcu1) (2), MV-0020 (Bcu2) (1), MV-0912 (Bcu1) (1)
Theben AG4132832254243MV-0021 (Bcu2) (11), MV-091A (Bcu1) (4), MV-0911 (Bcu1) (4), ETS plugin (3), MV-0912 (Bcu1) (3), MV-0020 (Bcu2) (1), MV-0001 (None) (1)
Albrecht Jung2962812531612ETS plugin (12), MV-0912 (Bcu1) (6), MV-0021 (Bcu2) (5), MV-0001 (None) (3), MV-091A (Bcu1) (2)
MDT technologies33927722669MV-0912 (Bcu1) (7), MV-091A (Bcu1) (2)
Busch-Jaeger Elektro28027526636ETS plugin (6), MV-091A (Bcu1) (2), MV-0912 (Bcu1) (1)
Merten324252163836MV-0021 (Bcu2) (72), ETS plugin (6), MV-0912 (Bcu1) (5), MV-091A (Bcu1) (3), MV-0001 (None) (2), MV-0020 (Bcu2) (1)
GIRA Giersiepen159130311971MV-0912 (Bcu1) (3), MV-0001 (None) (2), MV-091A (Bcu1) (2), ETS plugin (1)
Siemens11691531919ETS plugin (19), MV-0025 (Bcu2) (12), MV-0021 (Bcu2) (2), MV-0912 (Bcu1) (2), MV-0020 (Bcu2) (1), MV-0300 (PropertyBased) (1), MV-091A (Bcu1) (1)
Weinzierl Engineering GmbH80806614MV-091A (Bcu1) (6), MV-0001 (None) (5), MV-0912 (Bcu1) (3)
B.E.G.147736112MV-0025 (Bcu2) (6), MV-0001 (None) (2), MV-0912 (Bcu1) (2), MV-091A (Bcu1) (1), MV-0021 (Bcu2) (1)
Siemens HVAC78721656MV-0300 (PropertyBased) (21), MV-0300-01000000000000000000 (PropertyBased) (18), MV-0300-01000001000000000000 (PropertyBased) (11), MV-6800 (None) (5), MV-6900 (None) (1)
VIMAR95706541MV-0912 (Bcu1) (3), ETS plugin (1), MV-091A (Bcu1) (1)
GVS4343403MV-091A (Bcu1) (2), MV-0912 (Bcu1) (1)
Lingg & Janke4343142MV-0021 (Bcu2) (42)
STEINEL professional4040373MV-0912 (Bcu1) (2), MV-0001 (None) (1)
IPAS GmbH4327243MV-0025 (Bcu2) (2), MV-091A (Bcu1) (1)
Hugo Müller GmbH & Co KG432323
EAE2020173MV-0912 (Bcu1) (2), MV-091A (Bcu1) (1)
ise GmbH2120191ETS plugin (1)
Arcus-eds131313
TAPKO Technologies121266MV-0912 (Bcu1) (4), MV-091A (Bcu1) (1), MV-0001 (None) (1)
Theben HTS AG101091ETS plugin (1)
Enertex Bayern GmbH12963MV-0021 (Bcu2) (1), MV-0912 (Bcu1) (1), MV-091A (Bcu1) (1)
Schneider Electric Industries SAS8853MV-0912 (Bcu1) (1), MV-0001 (None) (1), MV-091A (Bcu1) (1)
Tense1177
Lithoss Design Switches6633MV-0021 (Bcu2) (3)
Iddero5532MV-0025 (Bcu2) (2)
ESYLUX4413
MEAN WELL Enterprises Co. Ltd.944
Elsner Elektronik GmbH333
Panasonic3312MV-0912 (Bcu1) (1), MV-091A (Bcu1) (1)
Thermokon Sensortechnik GmbH222
AIRZONE – ALTRA111
Sunricher111
Brumberg Leuchten111
CONTROLtronic111
DIVUS GmbH111
ELAUSYS111
Fujitsu General Limited111
Helios Ventilatoren111
Impolux GmbH / LEDIMAX111
Lunatone111
KNX Association111
TRILUX GmbH & Co. KG111
ekey biometric systems GmbH111

How to help

Everything above comes from product databases and offline checks. What moves a device from "supported" to "bus-tested", or from "not yet" to "supported", is evidence from real hardware:

Not worth reporting: products marked "needs ETS plugin". Their configuration lives in a manufacturer DLL; no capture changes that.